Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Chinese Journal of Traumatology ; (6): 352-355, 2018.
Article in English | WPRIM | ID: wpr-771657

ABSTRACT

PURPOSE@#Anterior cruciate ligament (ACL) repair was first described in the mid 1900's. However, due to poorly selected patients led to unsatisfactory early results. We aim to study the outcome of ACL repair in a carefully selected cohort.@*METHODS@#Thirteen consecutive patients of acute Type 1 (proximal ACL avulsion) were treated with arthroscopic ACL repair using a suture pull out technique. At the latest follow-up the patients were evaluated for Lysholm score, KT-1000 measurement and clinical assessment for any laxity.@*RESULTS@#At a mean follow-up of 31.3 months, none of the patients had any subjective laxity. The mean Lysholm score was 95 and instrumented laxity measurement did not reveal any significant laxity compared to the opposite knee.@*CONCLUSION@#The proximal ACL avulsion has healing potential similar to proximal MCL injuries. Performing microfracture of the lateral wall of the notch optimizes the healing environment by negating the effects of the synovial fluid. Performing ACL repair in a carefully selected patient leads to good short term results and saves the patient of a reconstruction procedure, at least in the immediate future.


Subject(s)
Adult , Aged , Female , Humans , Male , Young Adult , Anterior Cruciate Ligament , General Surgery , Anterior Cruciate Ligament Injuries , General Surgery , Anterior Cruciate Ligament Reconstruction , Methods , Follow-Up Studies , Fractures, Avulsion , General Surgery , Joint Instability , Sutures , Time Factors , Treatment Outcome
2.
Chinese Journal of Traumatology ; (6): 279-283, 2015.
Article in English | WPRIM | ID: wpr-316801

ABSTRACT

<p><b>PURPOSE</b>Subtrochanteric fractures of the femur are being managed successfully with various intramedullary and extramedulary implants with reasonable success. However, these implants require precise placement under image intensifier guidance, which exposes the surgeon to substantial amount of radiation. It also restricts the management of these fractures at peripheral centers where facility of image intensifiers is not available. Keeping this in mind we designed this study to identify if contralateral reversed distal femoral locking plate can be used successfully without the use of image intensifier.</p><p><b>METHODS</b>Twenty-four consecutive patients (18 men and 6 women) with a mean age of 28 years (range 19-47 years) suffering subtrochanteric fractures of the femur underwent open reduction and internal fixation with reversed contralateral distal femoral locking plate. The outcome was assessed at the mean follow-up period of 3.2 years (range 2-4.6 years) using the Harris hip score.</p><p><b>RESULTS</b>Twenty-one fractures united with the primary procedure, with a mean time of consolidation being 11 weeks (range, 9-16 weeks). One patient developed superficial suture line infection, which resolved with oral antibiotics. Another patient had a fall 3 weeks after surgery and broke the plate. Repeat surgery with reversed distal femoral locking compression plate was performed along with bone grafting and the fracture united. Two cases had nonunion, which went in for union after bone grafting. The mean Harris hip score at the time of final follow-up was 90.63 (range 82-97).</p><p><b>CONCLUSION</b>The reversed contralateral distal femoral plate is a biomechanically sound implant, which when used for fixation of the subtrochanteric fractures with minimal soft tissue stripping shows results comparable to those achieved by using other extramedullary implants as well as intramedullary devices. The added advantage of this implant is its usability in the absence of an image intensifier.</p>


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Bone Plates , Fracture Fixation, Internal , Methods , Hip Fractures , General Surgery
3.
Chinese Journal of Traumatology ; (6): 295-297, 2013.
Article in English | WPRIM | ID: wpr-358930

ABSTRACT

The combination of ipsilateral humeral fractures at three different levels namely proximal, shaft and supracondyle has been rarely defined in the literature. We present a case report on such a complex injury in a 10-year-old child after falling down from the second floor of his house while playing. To the best of our knowledge, no such case report exists in the English literature. We define it as double floating arm injury. Firstly, shaft of humerus was open reduced and fixed with 4.5 mm narrow dynamic compression plate. Then closed reduction and pinning of the supracondylar humerus under an image intensifier was obtained. Open reduction using deltopectoral approach to the proximal humerus was done and the fracture was fixed with three K-wires. Ipsilateral multiple fractures in children often result from high energy trauma. Immediate reduction and fixation is required. Usually surgeons need to treat simple fractures firstly, which makes the subsequent treatment of complex fractures easier.


Subject(s)
Child , Humans , Male , Humeral Fractures , Shoulder Fractures
4.
Chinese Journal of Traumatology ; (6): 339-343, 2013.
Article in English | WPRIM | ID: wpr-358919

ABSTRACT

<p><b>OBJECTIVE</b>Metaphyseal-diaphyseal fractures of the distal radius are a major treatment dilemma and orthopaedic surgeons have to pay due consideration to restoration of anatomy of distal radius together with rotation of the radial shaft and maintenance of radial bow and interosseous space. We performed this study to evaluate the clinic-radiological outcome of metaphyseal-diaphyseal fractures of the distal radius treated with long volar locking plates.</p><p><b>METHODS</b>This prospective study involved 27 patients (22 males and 5 females) with metaphyseal-diaphyseal fracture of the distal radius. Their mean age was (30.12+/-11.48) years (range 19-52 years) and the follow-up was 26.8 months (range 22-34 months). All patients underwent open reduction and internal fixation with a long volar locking plate. According to AO/OTA classification, there were 7 type A3, 13 type C2 and 7 type C3 fractures. Subjective assessment was done based on the disabilities of the arm, shoulder and hand (DASH) questionnaire. Functional evaluation was done by measuring grip strength and range of motion around the wrist and the radiological determinants included radial angle, radial length, volar angle and ulnar variance. The final assessment was done according to Gartland and Werley scoring system.</p><p><b>RESULTS</b>Postoperative radiological parameters were well maintained throughout the trial, and there was significant improvement in the functional parameters from 6 weeks to final follow-up. The average DASH scores improved from 37.5 at 6 weeks to 4.2 at final follow-up. Final assessment using Gartland and Werley scoring system revealed 66.67% (n equal to 18) excellent and 33.33% (n equal to 9) good results. There was one case of superficial infection which responded to antibiotics and another carpel tunnel syndrome which was managed conservatively.</p><p><b>CONCLUSION</b>Volar locking plate fixation for metaphyseal-diaphyseal fractures of distal radius is associated with excellent to good functional outcome, early rehabilitation and minimal complications.</p>


Subject(s)
Humans , Bone Plates , Fracture Fixation, Internal , Prospective Studies , Radius , Radius Fractures
5.
Chinese Journal of Traumatology ; (6): 365-367, 2013.
Article in English | WPRIM | ID: wpr-358913

ABSTRACT

Radial nerve palsy is the most common neurological involvement in humeral shaft fractures. But combined radial and median nerve injury in a closed diaphyseal fracture of the humerus is rare. Combined injury to both radial and median nerve can cause significant disability. A detailed clinical examination is therefore necessary following humeral shaft fractures. We report a patient with closed diaphyseal humeral fracture (AO 12A-2.3) together with radial and median nerve palsy, its management and review of the literature. As the patient had two nerves involved, surgical exploration was planned. Fracture was reduced and fixed with a 4.5 mm narrow dynamic compression plate. There was no external injury to both radial and median nerves on surgical exploration. Neurological recovery started at 3 weeks' follow-up. Complete recovery was seen at 12 weeks. Careful clinical examination is of the utmost importance in early diagnosis of combined nerve injuries, which allows better management and rehabilitation of the patient.


Subject(s)
Humans , Bone Plates , Humeral Fractures , General Surgery , Humerus , Median Nerve , Radial Neuropathy
SELECTION OF CITATIONS
SEARCH DETAIL